| Topside |
| Laser Wavelength (nm) |
Imaging |
Thermal XIVA
(SEI and TIVA) |
Photocarrier XIVA
(OBIC and LIVA) |
| 1340 |
Si, GaAs, SOI, MEMs |
Si, GaAs, SOI, MEMs |
-- |
| 1064 |
Si, GaAs, SOI, MEMs |
Si, GaAs, SOI, MEMs |
Si, MEMs |
| 860 |
Si, GaAs, SOI, MEMs |
Si, GaAs, SOI, MEMs |
Si, GaAs, MEMs |
| 532 |
Si, GaAs, SOI, MEMs |
Si, GaAs, SOI, MEMs |
Si, GaAs, SOI, MEMs |
| 430 |
Si, GaAs, SOI, MEMs |
Si, GaAs, SOI, MEMs |
Si, GaAs, SOI, MEMs |
| Backside |
| Laser
Wavelength (nm) |
Imaging |
Thermal XIVA
(SEI and TIVA) |
Photocarrier
XIVA
(OBIC and LIVA) |
| 1340 |
Si, GaAs, SOI, MEMs |
Si, GaAs, SOI, MEMs |
-- |
| 1064 |
Si, GaAs, SOI, MEMs |
GaAs, SOI |
Si, MEMs |
| 860 |
GaAs, SOI, MEMs |
-- |
GaAs, SOI |
Standard Laser
Sources:
(up to 3 sources can be placed in optical head) |
1064 nm - Frontside
and backside reflected-light, phase-contrast, OBIC, LIVA
1340 nm - Frontside and backside reflected-light, phase-contrast, TIVA, SEI
532 and 430 nm - Frontside reflected-light, phase-contrast, OBIC, LIVA, TIVA, SEI
Custom options available |
| Objectives: |
Four long-working
distance objectives on motorized turret 1X, 5X, 20X, and 50X standard
Other magnifications optional |
| Resolution (1064
nm): |
~ 0.7 micron at 50X
~ 0.4 micron with corrected high NA objective |
| Scanner: |
Galvanometer with
integrated position sensor |
| Pixel Clock: |
Position dependent |
| Image Sizes: |
256 ´ 256, 512 ´ 512, and 1024 ´ 1024 pixels Computer controlled |
| Field-of-View @
1X: |
~ 14 ´ 14 mm |
| Bits per Pixel: |
12 |
| Computer Operating
System: |
Windows NT |
| Computer
Accessories: |
21" monitor
DAQ card and breakout box
Network card
GPIB card
Zip drive |
| Software: |
OptoVision for data
acquisition, control, and image processing |
| Image Acquisition
Modes: |
Navigation, Blink,
Average |
| Size: |
17.0 ´ 10.5 ´ 8.5 inches (Optical Head)
Two 19-inch rack-mount chassis in table-side mount or free-standing rack (Electronics) |
| Weight: |
~ 25 pounds (Optical
Head) |
| Power
Requirements: |
15 amps @ 110 VAC,
50-60 Hz (including computer and peripherals) |
| Safety: |
Meets or exceeds
S2-2000 |
| Laser scanning microscope system includes standard
objectives, auxiliary electronics, computer with OptoVision application, computer console
with integrated electronics rack, onsite setup and training, one year of software
upgrades, and one-year warranty. Available options include choice of lasers, standard and
custom staging, Knights navigation software, and custom objectives. |
|