Left: three Optomet SMART Scan+ around a turbine blade in the lab; right: the color-coded vibration shape of the blade measured with them, shown on the CAD model.

Application report

3D vibration analysis for turbine blades and blisks

Measure natural frequencies, vibration shapes and dynamic strains without contact and visualize them directly on the 3D model.

Laser Doppler vibrometers from Optomet measure vibrations on turbine and compressor blades precisely and without contact, even under varying load and temperature conditions. With the SMART series lets you capture motion in one or three spatial directions. Measurements from multiple perspectives cover the entire turbine blade. The results are displayed directly on the 3D model. This report demonstrates the measurement procedure for a turbine blade and explains how the data can be used for vibration shape analysis, simulation validation, and component testing.

8 min read

Why measure turbine component vibrations over the entire surface in three dimensions?

Fluctuating pressure fields, thermal loads and repeated excitation place turbine blades under stress. When an excitation frequency is close to a natural frequency, strong vibrations can occur. These create dynamic loads and can cause critical stresses in the material. Considering static loads alone is therefore insufficient for design purposes. Three-dimensional vibrations and the number of loading cycles are also crucial.

Why a few sensor points are often not enough

Low-frequency, global vibration shapes can often be identified using just a few measurement positions. As frequency increases, however, spatial vibration patterns typically become more complex. Local maxima, nodal lines, and coupled motions can occur between widely spaced sensor positions and therefore go undetected.

Measurements using individual bonded sensors have limitations in this respect. They capture vibration behavior at only a few selected positions and can also affect the vibration behavior of lightweight turbine blades.

High measurement point density for local mode shapes

Scanning vibrometers measure vibrations at hundreds to many thousands of freely selectable measurement positions. The measurement grid can be tailored to the geometry, expected spatial wavelength, and relevant areas of the test object. This also reveals localized vibration shapes at higher frequencies.

Conventional sensors

  • A small number of measurement positions can identify global modes. Local maxima, nodal lines and coupled motion often go undetected between sensors.
  • Transducers, adhesive and cables alter the behavior of lightweight or thin-walled turbine blades.
  • Components require wiring and preparation.
  • Transducers cannot be attached to glowing-hot surfaces and can come loose at large amplitudes.

Scanning laser vibrometry

  • Hundreds to many thousands of freely selectable measurement points, tailored to the geometry, expected wavelength, and test object. This also reveals local modes at higher frequencies.
  • No sensor mass or cable forces: natural frequencies and mode shapes remain unaffected.
  • Measurements can be taken on almost any surface without preparation; reflective tape is generally unnecessary.
  • Even glowing-hot components and extremely large amplitudes can be measured. No other vibration measurement principle achieves a dynamic range of 220 dB and a measurement range of 0–50 MHz.

Measurement workflow: from the 3D model to measurement

For complex geometries in particular, it is useful to define measurement points directly on the 3D geometry rather than simply on a camera image. A CAD model or finite element model (FE model) provides a common coordinate system for this purpose. Measurement points, measurement directions, and results can thus be mapped unambiguously.

Measurement preparation starts with the CAD or FE model, before working with the camera image. Measurement points are defined on this digital geometry at the locations needed for subsequent comparison with the simulation.

  1. Define measurement points

    Measurement areas and point density are defined on the 3D geometry. Measurement points can be generated automatically and then adjusted individually. This creates a 360° measurement grid with uniform spacing, even on curved surfaces. Nodes from the FE model can be used directly as measurement points.

  2. Align the camera image and 3D model

    Geometric calibration takes place in two steps. First, an algorithm automatically aligns the 3D geometry with the camera image of the physical component.

  3. Align the lasers

    The laser then targets defined calibration points from the 3D model on the physical component. Using the corresponding mirror angles, the software calculates the exact position and orientation of the turbine blade relative to the measurement head. This establishes the geometric relationship between the test object and the vibrometer, allowing the mirror control system to target all measurement points defined in the 3D model automatically and precisely. Alignment takes just a few minutes per scanning head, with a complete 3D setup aligned in approximately 3 to 10 minutes.

  4. Create a digital representation

    After alignment, all geometric information about the measurement setup is known. The turbine blade, measurement heads, lines of sight, and measurement points share a common coordinate system. This creates a digital twin of the physical measurement setup.

  5. Excite the blade

    The turbine blade can be excited using a modal hammer, a shaker, a piezoelectric actuator, or acoustic excitation. A reference signal enables the calculation of frequency response functions (FRF). In the example shown, the load cell in the modal hammer provides this signal.

  6. Monitor data in real time

    During measurement, SMART Lab displays time-domain data, the reference signal, measurement progress and animations of the points already measured. This allows signal quality and settings to be checked early on.

Analyze frequency responses and vibration shapes

Using the measurement and reference signals, SMART Lab calculates the frequency response functions (FRF) for all measurement points and directions. For any selected frequency, the corresponding vibration shape can be animated directly on the component model, including at resonance frequencies. Analysis is possible in the spatial directions x, y and z as well as along the laser directions u, v and w, in each case relative to the reference signal.

Example: 3D full-body modal analysis of a turbine blade

A demonstration measurement illustrates the workflow using an approximately 30 × 10 cm turbine blade. The turbine blade was clamped and excited using an automated modal hammer. Three SMART Scan+ operated as a synchronized 3D system. They captured the visible surfaces from six calibrated perspectives around the turbine blade.

Test object
Clamped turbine blade, approx. 30 × 10 cm
Measurement system
3 × SMART Scan+ configured as a SMART 3D-Scan / full-body 3D setup
Perspectives
6 geometrically calibrated views
Measurement points
Around 800 points on the 3D model
Frequency range
Up to approximately 30 kHz
Excitation
Hammer excitation with a reference signal
Measurement time
Approx. 2 s per point; around 27 min of data acquisition
Calibration time
Approx. 3 min per perspective; around 18 min in total
Total duration
Around 45 min after setup, excluding initial setup time

The result: vibration shapes across all surfaces and in three directions

Full-body vibration shape of the measured blade on the CAD model.

Measurements from all perspectives are combined in a single project on the same 3D model. This makes it possible to analyze the front, rear and side surfaces together and animate their vibration shapes.

Three synchronized measurement directions allow motion to be determined in all three spatial directions. This enables motion within the surface (In-plane) and perpendicular to it (Out-of-plane) can be analyzed separately. Depending on the frequency, individual regions of the turbine blade move in different directions. The paired images illustrate this using the small fin as an example.

Validate FE models and determine dynamic strain

Visualize dynamic strain

Using the spatially resolved 3D motion of neighboring measurement points, SMART Lab also calculates dynamic strain. This reveals both the resonance frequencies and the locations where strain is particularly high. Non-contact measurement complements conventional strain gauges (DMS) and can reduce the number required for full-field investigations.

Compare measurements directly with simulations

Since the measurement points are defined on the 3D model, it is possible to compare measurements and simulations at the same locations. Higher-frequency and localized vibration shapes, in particular, reveal how accurately the model's material parameters, boundary conditions, and geometric details represent reality. The data support the validation of FE models in several ways:

  • Determine natural frequencies and modal parameters experimentally
  • Compare global and local vibration shapes
  • Position measurement points precisely at FE nodes and in critical regions
  • Export measurement and geometry data for CAE and modal analysis software
  • Support model updating with experimental data at high spatial resolution

Mistuning, component comparison, and End-of-Line testing

Small differences in geometry, material, coating, or manufacturing alter the natural frequencies and vibration shapes of individual turbine blades. Such variations between nominally identical turbine blades are known as Mistuning and, with reproducibly defined measurement positions, different components, individual turbine blades on a blisk, and conditions before and after manufacturing or repair can be compared:

  • Comparison of natural frequencies, frequency responses, and selected vibration shape metrics
  • Detection of variations between nominally identical turbine blades
  • Testing after manufacturing, coating, or repair
  • Reuse of defined measurement positions and test procedures
  • Customer-specific pass/fail assessment based on approved limits

SMART Multi-Fiber: simultaneous measurements, flexible configuration

Production testing does not always require a full scan with around 800 points. Depending on the defect being targeted and the metrics required, a few carefully selected measurement positions may be sufficient. Measuring several points simultaneously can reduce testing time.

For this purpose, SMART Multi-Fiber complements the scanning systems. Up to four Fiber Heads per unit take synchronized, phase-consistent measurements. Multiple systems can be linked to form a larger measurement network.

Depending on the configuration, autofocus measurement heads, compact measurement heads or 3D-Fiber-Heads are available. They can be used for reference, transfer path and comparative measurements, including in confined spaces or under demanding thermal conditions. Single-point 3D measurements are also possible.

Smart measurement systems for your testing needs

Frequently asked questions

Why are three vibrometers needed for a 3D measurement?

Each laser beam measures velocity along its measurement direction. Three synchronized beams from known geometric directions make it possible to determine motion in all three spatial directions.

How are measurement points mapped to the FE model?

Measurement points are defined directly on the imported 3D geometry. Calibrating the camera and lasers aligns the physical component and the vibrometers within the same coordinate system.

Is stitching required for full-body measurements?

No. Additional viewpoints are calibrated to the same 3D model. All points and results are therefore already in the shared project coordinate system.

Can measurements be performed on hot surfaces?

Yes, provided the measurement head and optical path are protected and sufficient backscattered light is available. Feasibility depends on the test setup and surface.

Can testing be automated?

Measurement sequences, measurement positions and customer-specific limits can be configured for recurring tests. Handling and process integration can be implemented in collaboration with automation partners as needed.

Which measurement strategy suits your application?

How many measurement points are needed? Which frequency range and excitation suit the task? And is a 1D measurement sufficient, or is a SMART 3D-Scan required? For an initial assessment, it helps us to know the component type, approximate dimensions, expected frequency range, test conditions and desired outcome.